NE-4000 Dual-channel Syringe Pump
NE-4000 offers full-featured programmable infusion and withdrawal. It is able to hold two syringes up to 60 mL with pumping rates from 25 µL/min to 100 mL/min. A 140 mL syringe can be filled up to 120 mL.
NE-4000 Dual-channel Syringe Pump
Dimensions: 229 x 146 x 114 mm (D x W x H)
Working mode: Infusion/withdrawal
Channels: 2
Motor type: Step motor
Motor step per revolution: 200
Microstepping: 1/8 to 1/2 depending on motor speed
Advance per step: 0.4252 µm to 1.7009 µm depending on motor speed
Maximum speed: 184 mm/min
Minimum speed: 1.3 µm/min
Linear force: > 400 N at minimum speed, 80 N at maximum speed
Accuracy: Within +/- 1% over length of syringe, exclusive of syringe variations
Flow rate: 25 µL/min - 100 mL/min
Syringe size: 1 - 60 mL (140 mL partially filled)
Number of program phases: 41
Comm. interface: RS-232 (network up to 100 pumps)
Power supply: Unregulated linear external wall adapter, country and power source specific (or compatible regulated power supply)
Weight: 1.63 Kg
Certificates: CE
NE-4000
NE-1600 Multi-channel (6) Syringe Pump
Multi-syringe pump with the same full-featured programmable capabilities as the NE-1000 (up to 6 channels with infusion/withdrawal). NE-1600 holds 2, 4 or 6 syringes of up to 60 mL each or 2 or 4 syringes up to 140 mL each with infusion rates from 0.008 µL/min to 40 mL/min.
NE-1600 Multi-channel (6) Syringe Pump
Dimensions: 260 x 381 x 127 mm (D x W x H)
Working mode: Infusion/withdrawal
Channels: up to 6
Motor type: Step motor
Motor step per revolution: 200
Microstepping: 1/8 to 1/2 depending on motor speed
Advance per step: 0.1323 µm to 0.5292 µm depending on motor speed
Maximum speed: 35 mm/min
Minimum speed: 0.4 µm/min
Linear force: > 700 N at minimum speed, 130 N at maximum speed
Accuracy: Within +/- 1% over length of syringe, exclusive of syringe variations
Flow rate: 8 nL/min - 20 mL/min
Syringe size: 0.5 µL - 140 mL
Number of program phases: 41
Comm. interface: RS-232 (network up to 100 pumps)
Power supply: Unregulated linear external wall adapter, country and power source specific (or compatible regulated power supply)
Weight: 4.6 Kg
Certificates: CE
NE-1600
NE-1800 Multi-channel (8) Syringe Pump
Multi-syringe pump with the same full-featured programmable capabilities as the NE-1000 (up to 8 channels). NE-1800 series allows infusion and withdrawal, and holds 2, 4, 6 or 8 syringes of up to 10 mL each with infusion rates from 0.008 µL/min to 5,7 mL/min.
NE-1800 Multi-channel (8) Syringe Pump
Dimensions: 260 x 381 x 127 mm (D x W x H)
Working mode: Infusion/withdrawal
Channels: up to 8
Motor type: Step motor
Motor step per revolution: 200
Microstepping: 1/8 to 1/2 depending on motor speed
Advance per step: 0.1323 µm to 0.5292 µm depending on motor speed
Maximum speed: 35 mm/min
Minimum speed: 0.4 µm/min
Linear force: > 700 N at minimum speed, 130 N at maximum speed
Accuracy: Within +/- 1% over length of syringe, exclusive of syringe variations
Flow rate: 8 nL/min - 20 mL/min
Syringe size: 0.5 µL - 140 mL
Number of program phases: 41
Comm. interface: RS-232 (network up to 100 pumps)
Power supply: Unregulated linear external wall adapter, country and power source specific (or compatible regulated power supply)
Weight: 4.6 Kg
Certificates: CE
NE-1800
Thin-layer Microfluidic Platinum Interdigitated Sensor (10/10 µm)
15 pairs interdigitated platinum electrodes (10/10 µm, electrode/gap) integrated into a 40-µm height SU8 microchannel. Useful for FIA systems. Compatible with AIO and Multi8x AIO cell with TL add-ons.
Thin-layer Microfluidic Platinum Interdigitated Sensor (10/10 µm)
Dimensions: 10 x 6 x 0.75 mm
Substrate: Glass
Microfluidic stage: EPON SU8 resin
Channel width: 250 µm / 1mm (EC-cell)
Channel height: 40 µm
Inlet / outlet: 0.7 mm Ø
Electrodes material: Ti / Pt
Electrodes thickness: 50/150 nm
Microelectrode width: 10 µm
Microelectrode gap: 10 µm
Number of fingers: 15 pairs
Channel volume: 55 nL
Applications: Impedance, capacitance and conductivity measurements, fuel cells
Contents: 20 units/box
TL-IDA1-Pt (20 units/box)
Thin-layer Microfluidic Platinum Interdigitated Sensor (10/10 µm)
15 pairs interdigitated platinum electrodes (10/10 µm, electrode/gap) integrated into a 40-µm height SU8 microchannel. Useful for FIA systems. Compatible with AIO and Multi8x AIO cell with TL add-ons.
Thin-layer Microfluidic Platinum Interdigitated Sensor (10/10 µm)
Dimensions: 10 x 6 x 0.75 mm
Substrate: Glass
Microfluidic stage: EPON SU8 resin
Channel width: 250 µm / 1mm (EC-cell)
Channel height: 40 µm
Inlet / outlet: 0.7 mm Ø
Electrodes material: Ti / Pt
Electrodes thickness: 50/150 nm
Microelectrode width: 10 µm
Microelectrode gap: 10 µm
Number of fingers: 15 pairs
Channel volume: 55 nL
Applications: Impedance, capacitance and conductivity measurements, fuel cells
Contents: 20 units/box
TL-IDA1-Pt (20 units/box)
Thin-layer Microfluidic Single Platinum Sensor
Three platinum electrodes approach integrated into a 40-µm height SU8 microchannel. Useful for FIA systems. Compatible with AIO and Multi8x AIO cell with TL add-ons.
Thin-layer Microfluidic Single Platinum Sensor
Dimensions: 10 x 6 x 0.75 mm
Substrate: Glass
Microfluidic stage: EPON SU8 resin
Channel width: 250 µm / 1mm (EC-cell)
Channel height: 40 µm
Inlet / outlet: 0.7 mm Ø
Electrodes material: Ti / Pt
Electrodes thickness: 50/150 nm
WE size: 0.3 mm2
Channel volume: 55 nL
Applications: Electroanalysis, flow systems, nanotechnology, chemical sensors, biosensors
Contents: 20 units/box
TL-SE1-Pt (20 units/box)
Thin-layer Microfluidic Single Platinum Sensor
Three platinum electrodes approach integrated into a 40-µm height SU8 microchannel. Useful for FIA systems. Compatible with AIO and Multi8x AIO cell with TL add-ons.
Thin-layer Microfluidic Single Platinum Sensor
Dimensions: 10 x 6 x 0.75 mm
Substrate: Glass
Microfluidic stage: EPON SU8 resin
Channel width: 250 µm / 1mm (EC-cell)
Channel height: 40 µm
Inlet / outlet: 0.7 mm Ø
Electrodes material: Ti / Pt
Electrodes thickness: 50/150 nm
WE size: 0.3 mm2
Channel volume: 55 nL
Applications: Electroanalysis, flow systems, nanotechnology, chemical sensors, biosensors
Contents: 20 units/box
TL-SE1-Pt (20 units/box)
Thin-layer Microfluidic Single Gold Sensor
Three gold electrode approach integrated into a 40-µm height SU8 microchannel. Useful for FIA systems for developing enzyme and immunosensors. Compatible with AIO and Multi8x AIO cell with TL add-ons.
Thin-layer Microfluidic Single Gold Sensor
Dimensions: 10 x 6 x 0.75 mm
Substrate: Glass
Microfluidic stage: EPON SU8 resin
Channel width: 250 µm / 1mm (EC-cell)
Channel height: 40 µm
Inlet / outlet: 0.7 mm Ø
Electrodes material: Ti / Au
Electrodes thickness: 50/150 nm
WE size: 0.3 mm2
Channel volume: 55 nL
Applications: Electroanalysis, flow systems, nanotechnology, chemical sensors, biosensors
Contents: 20 units/box
TL-SE1-Au (20 units/box)
Thin-layer Microfluidic Single Gold Sensor
Three gold electrode approach integrated into a 40-µm height SU8 microchannel. Useful for FIA systems for developing enzyme and immunosensors. Compatible with AIO and Multi8x AIO cell with TL add-ons.
Thin-layer Microfluidic Single Gold Sensor
Dimensions: 10 x 6 x 0.75 mm
Substrate: Glass
Microfluidic stage: EPON SU8 resin
Channel width: 250 µm / 1mm (EC-cell)
Channel height: 40 µm
Inlet / outlet: 0.7 mm Ø
Electrodes material: Ti / Au
Electrodes thickness: 50/150 nm
WE size: 0.3 mm2
Channel volume: 55 nL
Applications: Electroanalysis, flow systems, nanotechnology, chemical sensors, biosensors
Contents: 20 units/box
TL-SE1-Au (20 units/box)
Thin-layer Microfluidic Platinum Interdigitated Sensor (5/5 µm)
30 pairs interdigitated platinum electrodes (5/5 µm, electrode/gap) integrated into 40-µm height SU8 microchannel. Useful for FIA systems. Compatible with AIO and Multi8x AIO cell with TL add-ons.
Thin-layer Microfluidic Platinum Interdigitated Sensor (5/5 µm)
Dimensions: 10 x 6 x 0.75 mm
Substrate: Glass
Microfluidic stage: EPON SU8 resin
Channel width: 250 µm / 1mm (EC-cell)
Channel height: 40 µm
Inlet / outlet: 0.7 mm Ø
Electrodes material: Ti / Pt
Electrodes thickness: 50/150 nm
Microelectrode width: 5 µm
Microelectrode gap: 5 µm
Number of fingers: 30 pairs
Channel volume: 55 nL
Applications: Impedance, capacitance and conductivity measurements, fuel cells
Contents: 20 units/box
TL-IDA5-Pt (20 units/box)
Thin-layer Microfluidic Platinum Interdigitated Sensor (5/5 µm)
30 pairs interdigitated platinum electrodes (5/5 µm, electrode/gap) integrated into 40-µm height SU8 microchannel. Useful for FIA systems. Compatible with AIO and Multi8x AIO cell with TL add-ons.
Thin-layer Microfluidic Platinum Interdigitated Sensor (5/5 µm)
Dimensions: 10 x 6 x 0.75 mm
Substrate: Glass
Microfluidic stage: EPON SU8 resin
Channel width: 250 µm / 1mm (EC-cell)
Channel height: 40 µm
Inlet / outlet: 0.7 mm Ø
Electrodes material: Ti / Pt
Electrodes thickness: 50/150 nm
Microelectrode width: 5 µm
Microelectrode gap: 5 µm
Number of fingers: 30 pairs
Channel volume: 55 nL
Applications: Impedance, capacitance and conductivity measurements, fuel cells
Contents: 20 units/box
TL-IDA5-Pt (20 units/box)
Thin-layer Microfluidic Gold Interdigitated Sensor (10/10 µm)
15 pairs interdigitated gold electrodes (10/10 µm, electrode/gap) integrated into a 40-µm height SU8 microchannel. Useful for FIA systems. Compatible with AIO and Multi8x AIO cell with TL add-ons.
Thin-layer Microfluidic Gold Interdigitated Sensor (10/10 µm)
Dimensions: 10 x 6 x 0.75 mm
Substrate: Glass
Microfluidic stage: EPON SU8 resin
Channel width: 250 µm / 1mm (EC-cell)
Channel height: 40 µm
Inlet / outlet: 0.7 mm Ø
Electrodes material: Ti / Au
Electrodes thickness: 50/150 nm
Microelectrode width: 10 µm
Microelectrode gap: 10 µm
Number of fingers: 15 pairs
Channel volume: 55 nL
Applications: Impedance, capacitance and conductivity measurements, fuel cells
Contents: 20 units/box
TL-IDA1-Au (20 units/box)
93 Products. View all
We ship the products under strict security measures, ensuring their protection...
More information