Shop

LSP01-1A Single-channel Syringe Pump

LSP01-1A Single-channel Syringe Pump

Just infusion single-channel syringe pump with 5 µm/min minimum linear speed. The acceptable syringe specification is from 10 μL to 60 mL Compatible with AIO-Cell, Flow-cell and TL add-ons, and thin-film electrodes.

LSP01-1A Single-channel Syringe Pump

Dimensions: 280 x 210 x 140 mm (D x W x H)

Working mode: Infusion

Channels: 1

Advance per step: 0.156 µm

Linear force: > 90 N

Accuracy: ≤ ± 0.5% error in the condition of > 30% of max. infusion distance

Flow rate: 0.83 nL/min – 54.2 mL/min

Syringe size: 10 µL – 60 mL

Comm. interface: RS485

Pump stroke: 140 mm

Max. linear rate: 65 mm/min

Min. linear rate: 5 µm/min

State signal output: 2 output signals (OC gate signal) to indicate start/stop and direction

Control signal input: Falling edge or TLL signal to control start/stop

Display: Display volume, flow rate or linear speed (128x64 graphic LCD)

Power off memory: Storing the running parameters automatically

Power supply: AC 90V-260V / 15W

Operating temperature: 0 to 40 ºC

Humidity: < 80%

Weight: 3.6 Kg

Certificates: CE

LSP01-1A

LSP01-2A Single-channel Syringe Pump

LSP01-2A Single-channel Syringe Pump

Just infusion high-precision single-channel syringe pump with 1 µm/min minimum linear speed. The acceptable syringe specification is from 10 μL to 60 mL Compatible with AIO-Cell, Flow-cell and TL add-ons, and thin-film electrodes.

LSP01-2A Single-channel Syringe Pump

Dimensions: 280 x 210 x 140 mm (D x W x H)

Working mode: Infusion

Channels: 1

Advance per step: 0.031 µm

Linear force: > 90 N

Accuracy: ≤ ± 0.5% error in the condition of > 30% of max. infusion distance

Flow rate: 0.16 nL/min – 10.8 mL/min

Syringe size: 10 µL – 60 mL

Comm. interface: RS485

Pump stroke: 140 mm

Max. linear rate: 13 mm/min

Min. linear rate: 1 µm/min

State signal output: 2 output signals (OC gate signal) to indicate start/stop and direction

Control signal input: Falling edge or TLL signal to control start/stop

Display: Display volume, flow rate or linear speed (128x64 graphic LCD)

Power off memory: Storing the running parameters automatically

Power supply: AC 90V-260V / 15W

Operating temperature: 0 to 40 ºC

Humidity: < 80%

Weight: 3.6 Kg

Certificates: CE

LSP01-2A

TJ-3A Single-channel Syringe Pump

TJ-3A Single-channel Syringe Pump

Infusion/withdrawal single-channel syringe pump. The acceptable syringe specifications are from 10 µL to 60 mL. Suitable for high accuracy and small flow rate liquid transferring.

TJ-3A Single-channel Syringe Pump

Dimensions: 170 x 108 x 70 mm / 245 x 100 x 95 mm (controller / drive unit) (D X W X H)

Working mode: Infusion, withdrawal, infusion/withdrawal, withdrawal/infusion, continuous

Channels: 1

Advance per step: 0.165 µm

Linear force: > 90 N

Accuracy: ≤ ± 0.5% error in the condition of > 30% of max. infusion distance

Flow rate: 0.139 µL/min – 52.9 mL/min

Syringe size: 1 - 60 mL

Comm. interface: RS485

Pump stroke: 90 mm

Max. linear rate: 79.4 mm/min

Min. linear rate: 7.9 µm/min

State signal output: 2 output signals (OC gate signal) to indicate start/stop and direction

Control signal input: Falling edge or TLL signal to control start/stop

Display: Display volume, flow rate or linear speed (128x64 graphic LCD)

Power off memory: Storing the running parameters automatically

Power supply: AC 90V-260V / 10W

Operating temperature: 0 to 40 ºC

Humidity: < 80%

Weight: 0.8 Kg (controller) 1.3 Kg (drive unit)

Certificates: CE

TJ-3A/W0109-1B

LSP02-1B Dual-channel Syringe Pump

LSP02-1B Dual-channel Syringe Pump

2-channels syringe pump with infusion/ withdrawal mode. The acceptable syringe specification is from 10 µL to 140 mL. Suitable for high accuracy and small flow rate liquid transferring.

LSP02-1B Dual-channel Syringe Pump

Dimensions: 280 x 250 x 140 mm (D x W x H)

Working mode: Infusion, withdrawal, infusion/withdrawal, withdrawal/infusion, continuous

Channels: 2

Advance per step: 0.156 µm

Linear force: > 180 N

Accuracy: ≤ ± 0.5% error in the condition of > 30% of max. infusion distance

Flow rate: 0.83 nL/min – 150.5 mL/min

Syringe size: 10 µL – 140 mL

Comm. interface: RS485

Pump stroke: 140 mm

Max. linear rate: 130 mm/min

Min. linear rate: 5 µm/min

State signal output: 2 output signals (OC gate signal) to indicate start/stop and direction

Control signal input: Falling edge or TLL signal to control start/stop

Display: Display volume, flow rate or linear speed (128x64 graphic LCD)

Power off memory: Storing the running parameters automatically

Power supply: AC 90V-260V / 20W

Operating temperature: 0 to 40 ºC

Humidity: < 80%

Weight: 4.3 Kg

Certificates: CE

LSP02-1B

Basic Pack

Flow System - Basic Pack

The basic pack includes:

  • Fitting  nuts (1/4" - 28 UNF - 1/16" OD tubing) - 5 units
  • Ferrules PTFE/SS (1/4" - 28 UNF - 1/16" OD tubing) - 5 units
  • PTFE tubing (OD: 1,6mm - 1/16" - ID: 0,8 mm) - 1 m
  • Plastic syringes (10 mL) - 5 units
  • Disposable scalpel - 1 unit

Flow System - Basic Pack

Contents: Fitting nuts + ferrules + tubing + syringes + scalpel

Details: Other pack options are available under request.

B-PACK

Basic-Plus Pack

Flow System - Basic-Plus Pack

The plus-pack includes:

  • Fitting  nuts (1/4" - 28 UNF - 1/16" OD tubing) - 5 units
  • Ferrules PTFE/SS (1/4" - 28 UNF - 1/16" OD tubing) - 5 units
  • PTFE tubing (OD: 1,6mm - 1/16" - ID: 0,8 mm) - 1 m
  • Glass reservoir (GL32 thread - 50 mL)  with standard cap - 2 units
  • Bottle cap (GL32 thread/ 2 x Luer ports) - 2 units
  • Plastic syringes (10 mL) - 5 units
  • Disposable scalpel - 1 unit

Flow System - Basic-Plus Pack

Contents: Fitting nuts + ferrules + tubing + reservoirs + syringes + scalpel

Details: Other pack options are available under request.

B-PACK+

High Voltage Cable

High Voltage Cable

Compatible with MicruX® HVStat and microfluidic chip holder to connect the high voltage electrodes.

High Voltage Cable

Dimensions: 50 cm long

Contents: 1 x HV cable

Details: Accessory for MicruX® HVStat electrophoresis system.

MXF-HVCAB

Bipotentiostat cable

Bipotentiostat Cable

Compatible with MicruX® HVStat and microfluidic chip holder to connect the electrodes of detection system.

Bipotentiostat Cable

Dimensions: 50 cm long

Contents: 1 x bipot cable

Details: Accessory for MicruX® HVStat electrophoresis system.

MXF-BIPOTCAB

MES Based Buffer Solution

MES Based Buffer Solution

Buffer substance provided as single dose specially developed to carry out electrophoresis separations in microfluidic devices with electrochemical detection. Buffer is available in different pH between 5.0 and 7.0.

MES Based Buffer Solution

Contents: 10 x Single Bottle - Buffer Substance

Details: The buffer substance should be diluted in distilled water to get the final concentration/pH.

MXF-MES

Full System Pack

Flow System - Full Pack

The full-pack contains all the accesories for using using MicruX’ thin-film (micro)electrodes in flow systems with All-in-One platform. This pack includes:

  • AIO-CELL-1x + 25 standard electrodes.
  • Peristaltic pump and injection valve.
  • Fittings, ferrules and tubing.
  • Glass reservoir and other material.

Flow System - Full Pack

Contents: AIO Cell + 1 Add-on + 25 standard thin-film electrodes + fitting system + reservoir + other accessories

Details: Other pack options; with different peristaltic or syringe pumps, accessories…, are also available on demand. Packs might be customized taking into account the specific requirements of customers.

F-PACK-AIO

iHVStat Electrophoresis System

iHVStat Electrophoresis System

Integrated, automated, portable and miniaturized microfluidic electrophoresis system integrating HV power supply and bipotentiostat. High voltage up to +/- 3kV and DC potential up to +/- 2V. Fully controlled by software. Bluetooth and cable connections available. Compatible with microfluidic chip holder and microchips electrophoresis.

iHVStat Electrophoresis System

Dimensions: 165 x 150 x 95 mm (L x W x H)

Interfacing: Serial RS232/ USB Adapter/ wireless (Bluetooth)

LED indicators: power, Bluetooth, cable

Battery power: LiPo - 3300 mAh

HV channels/outputs: 1/4

HV outputs polarity: Positive / negative

HV Output Voltage: ± 3000 V

HV Max. Output Current: 0.34 mA

DC-potential range: ± 2.00 V

DC-potential resolution: 1 mV

DC-offset error: ± 1 mV

Accuracy: < 0.1%

Current ranges: 1 nA to 1 μA (4 ranges)

Maximun DC current: ± 2 μA

Weight: < 0.5 Kg

Certificates: CE

Details: PC software control - MicruX Manager. Integrated interface for microfluidic chip holder. Cabeless.

iHVSTAT

iHVStat Electrophoresis System

iHVStat Electrophoresis System

Integrated, automated, portable and miniaturized microfluidic electrophoresis system integrating HV power supply and bipotentiostat. High voltage up to +/- 3kV and DC potential up to +/- 2V. Fully controlled by software. Bluetooth and cable connections available. Compatible with microfluidic chip holder and microchips electrophoresis.

iHVStat Electrophoresis System

Dimensions: 165 x 150 x 95 mm (L x W x H)

Interfacing: Serial RS232/ USB Adapter/ wireless (Bluetooth)

LED indicators: power, Bluetooth, cable

Battery power: LiPo - 3300 mAh

HV channels/outputs: 1/4

HV outputs polarity: Positive / negative

HV Output Voltage: ± 3000 V

HV Max. Output Current: 0.34 mA

DC-potential range: ± 2.00 V

DC-potential resolution: 1 mV

DC-offset error: ± 1 mV

Accuracy: < 0.1%

Current ranges: 1 nA to 1 μA (4 ranges)

Maximun DC current: ± 2 μA

Weight: < 0.5 Kg

Certificates: CE

Details: PC software control - MicruX Manager. Integrated interface for microfluidic chip holder. Cabeless.

iHVSTAT

93 Products. View all

Returns

All the information that you should know about our returns policy...

More information

Contact

Contact us to solve your doubts or answer your questions. We can help you!

More information

Delivery

We ship the products under strict security measures, ensuring their protection...

More information

subscribe to our monthly newsletter