Microfluidic Solutions

ME Single-Channel with Platinum InterDigitated Array Microelectrodes

ME Single-Channel with Platinum InterDigitated Array Microelectrodes

Two sets of three 10-µm platinum microelectrodes and 10-µm gap with an interdigitated (IDA) approach and 250-µm reference and auxiliary electrodes. Two working electrodes individually addressable. Detection system placed at the outlet of the separation channel with an end-channel approach. Compatible with microfluidic chip holder, HVStat and iHVStat instrument.

ME Single-Channel with Platinum InterDigitated Array Microelectrodes

Material: Glass/SU8

Dimensions: 38 x 13 x 0.8 mm (L x W x H)

Injection channel length: 10 mm

Separation channel length: 35 mm

Microchannel geometry: rectangular

Channel width: 50 µm

Channel height: 20 µm

Inlet / outlet: 2 mm Ø

Electrodes material: Ti / Pt

Electrodes thickness: 50/150 nm

Microelectrode width: 10 µm

Microelectrode gap: 10 µm

Number of fingers: 3 pairs

Reference electrode width: 250µm

Auxiliary electrode width: 250µm

Applications: Electrophoretic separations of organic compounds, cations, anions, DNA, peptides, etc.

Contents: from 1 chip

MCE-SU8-IDA-Pt005T

Thin-layer Microfluidic Single Gold Sensor

Thin-layer Microfluidic Single Gold Sensor

Three gold electrode approach integrated into a 40-µm height SU8 microchannel. Useful for FIA systems for developing enzyme and immunosensors. Compatible with AIO and Multi8x AIO cell with TL add-ons.

Thin-layer Microfluidic Single Gold Sensor

Dimensions: 10 x 6 x 0.75 mm

Substrate: Glass

Microfluidic stage: EPON SU8 resin

Channel width: 250 µm / 1mm (EC-cell)

Channel height: 40 µm

Inlet / outlet: 0.7 mm Ø

Electrodes material: Ti / Au

Electrodes thickness: 50/150 nm

WE size: 0.3 mm2

Channel volume: 55 nL

Applications: Electroanalysis, flow systems, nanotechnology, chemical sensors, biosensors

Contents: 20 units/box

TL-SE1-Au (20 units/box)

Thin-layer Microfluidic Single Platinum Sensor

Thin-layer Microfluidic Single Platinum Sensor

Three platinum electrodes approach integrated into a 40-µm height SU8 microchannel. Useful for FIA systems. Compatible with AIO and Multi8x AIO cell with TL add-ons.

Thin-layer Microfluidic Single Platinum Sensor

Dimensions: 10 x 6 x 0.75 mm

Substrate: Glass

Microfluidic stage: EPON SU8 resin

Channel width: 250 µm / 1mm (EC-cell)

Channel height: 40 µm

Inlet / outlet: 0.7 mm Ø

Electrodes material: Ti / Pt

Electrodes thickness: 50/150 nm

WE size: 0.3 mm2

Channel volume: 55 nL

Applications: Electroanalysis, flow systems, nanotechnology, chemical sensors, biosensors

Contents: 20 units/box

TL-SE1-Pt (20 units/box)

Microfluidic Chip Holder

Microfluidic Chip Holder

Basic interface for microchips electrophoresis integrating electrode connections for detection and HV as well as wells for buffer solution, sample waste and detection. Compatible with microfluidic electrophoresis chips, HVStat and iHVStat instruments.

Microfluidic Chip Holder

Material: PMMA

Dimensions: 100 x 65 x 15 mm (L x W x H)

Applications: Electrophoretic separations of organic compounds, cations, anions, DNA, peptides, etc.

Contents: Microfluidic Chip Interface

Details: Integrated wells, HV electrodes, 2-mm female bananas. Reusable.

MCE-HOLDER-DC02

iHVStat Electrophoresis System

iHVStat Electrophoresis System

Integrated, automated, portable and miniaturized microfluidic electrophoresis system integrating HV power supply and bipotentiostat. High voltage up to +/- 3kV and DC potential up to +/- 2V. Fully controlled by software. Bluetooth and cable connections available. Compatible with microfluidic chip holder and microchips electrophoresis.

iHVStat Electrophoresis System

Dimensions: 165 x 150 x 95 mm (L x W x H)

Interfacing: Serial RS232/ USB Adapter/ wireless (Bluetooth)

LED indicators: power, Bluetooth, cable

Battery power: LiPo - 3300 mAh

HV channels/outputs: 1/4

HV outputs polarity: Positive / negative

HV Output Voltage: ± 3000 V

HV Max. Output Current: 0.34 mA

DC-potential range: ± 2.00 V

DC-potential resolution: 1 mV

DC-offset error: ± 1 mV

Accuracy: < 0.1%

Current ranges: 1 nA to 1 μA (4 ranges)

Maximun DC current: ± 2 μA

Weight: < 0.5 Kg

Certificates: CE

Details: PC software control - MicruX Manager. Integrated interface for microfluidic chip holder. Cabeless.

iHVSTAT

HVStat Electrophoresis System

HVStat Electrophoresis System

Automated, portable and miniaturized microfluidic electrophoresis system integrating HV power supply and bipotentiostat. High voltage up to +/- 3kV and DC potential up to +/- 2V. Fully controlled by software. Bluetooth and cable connections available. Compatible with microfluidic chip holder and microchips electrophoresis.

HVStat Electrophoresis System

Dimensions: 165 x 150 x 85 mm (L x W x H)

Interfacing: Serial RS232/ USB Adapter/ wireless (Bluetooth)

LED indicators: power, Bluetooth, cable

Battery power: LiPo - 3300 mAh

HV channels/outputs: 1/4

HV outputs polarity: Positive / negative

HV Output Voltage: ± 3000 V

HV Max. Output Current: 0.34 mA

DC-potential range: ± 2.00 V

DC-potential resolution: 1 mV

DC-offset error: ± 1 mV

Accuracy: < 0.1%

Current ranges: 1 nA to 1 μA (4 ranges)

Maximun DC current: ± 2 μA

Weight: < 0.5 Kg

Certificates: CE

Details: PC software control - MicruX Manager. External cables for interfacing microfluidic chip holder.

HVSTAT

Thin-layer Microfluidic Gold Interdigitated Sensor (10/10 µm)

Thin-layer Microfluidic Gold Interdigitated Sensor (10/10 µm)

15 pairs interdigitated gold electrodes (10/10 µm, electrode/gap) integrated into a 40-µm height SU8 microchannel. Useful for FIA systems. Compatible with AIO and Multi8x AIO cell with TL add-ons.

Thin-layer Microfluidic Gold Interdigitated Sensor (10/10 µm)

Dimensions: 10 x 6 x 0.75 mm

Substrate: Glass

Microfluidic stage: EPON SU8 resin

Channel width: 250 µm / 1mm (EC-cell)

Channel height: 40 µm

Inlet / outlet: 0.7 mm Ø

Electrodes material: Ti / Au

Electrodes thickness: 50/150 nm

Microelectrode width: 10 µm

Microelectrode gap: 10 µm

Number of fingers: 15 pairs

Channel volume: 55 nL

Applications: Impedance, capacitance and conductivity measurements, fuel cells

Contents: 20 units/box

TL-IDA1-Au (20 units/box)

Thin-layer Microfluidic Platinum Interdigitated Sensor (10/10 µm)

Thin-layer Microfluidic Platinum Interdigitated Sensor (10/10 µm)

15 pairs interdigitated platinum electrodes (10/10 µm, electrode/gap) integrated into a 40-µm height SU8 microchannel. Useful for FIA systems. Compatible with AIO and Multi8x AIO cell with TL add-ons.

Thin-layer Microfluidic Platinum Interdigitated Sensor (10/10 µm)

Dimensions: 10 x 6 x 0.75 mm

Substrate: Glass

Microfluidic stage: EPON SU8 resin

Channel width: 250 µm / 1mm (EC-cell)

Channel height: 40 µm

Inlet / outlet: 0.7 mm Ø

Electrodes material: Ti / Pt

Electrodes thickness: 50/150 nm

Microelectrode width: 10 µm

Microelectrode gap: 10 µm

Number of fingers: 15 pairs

Channel volume: 55 nL

Applications: Impedance, capacitance and conductivity measurements, fuel cells

Contents: 20 units/box

TL-IDA1-Pt (20 units/box)

Thin-layer Microfluidic Gold Interdigitated Sensor (5/5 µm)

Thin-layer Microfluidic Gold Interdigitated Sensor (5/5 µm)

30 pairs interdigitated gold electrodes (5/5 µm, electrode/gap) integrated into a 40-µm height SU8 microchannel. Useful for FIA systems. Compatible with AIO and Multi8x AIO cell with TL add-ons.

Thin-layer Microfluidic Gold Interdigitated Sensor (5/5 µm)

Dimensions: 10 x 6 x 0.75 mm

Substrate: Glass

Microfluidic stage: EPON SU8 resin

Channel width: 250 µm / 1mm (EC-cell)

Channel height: 40 µm

Inlet / outlet: 0.7 mm Ø

Electrodes material: Ti / Au

Electrodes thickness: 50/150 nm

Microelectrode width: 5 µm

Microelectrode gap: 5 µm

Number of fingers: 30 pairs

Channel volume: 55 nL

Applications: Impedance, capacitance and conductivity measurements, fuel cells

Contents: 20 units/box

TL-IDA5-Au (20 units/box)

Thin-layer Microfluidic Platinum Interdigitated Sensor (5/5 µm)

Thin-layer Microfluidic Platinum Interdigitated Sensor (5/5 µm)

30 pairs interdigitated platinum electrodes (5/5 µm, electrode/gap) integrated into 40-µm height SU8 microchannel. Useful for FIA systems. Compatible with AIO and Multi8x AIO cell with TL add-ons.

Thin-layer Microfluidic Platinum Interdigitated Sensor (5/5 µm)

Dimensions: 10 x 6 x 0.75 mm

Substrate: Glass

Microfluidic stage: EPON SU8 resin

Channel width: 250 µm / 1mm (EC-cell)

Channel height: 40 µm

Inlet / outlet: 0.7 mm Ø

Electrodes material: Ti / Pt

Electrodes thickness: 50/150 nm

Microelectrode width: 5 µm

Microelectrode gap: 5 µm

Number of fingers: 30 pairs

Channel volume: 55 nL

Applications: Impedance, capacitance and conductivity measurements, fuel cells

Contents: 20 units/box

TL-IDA5-Pt (20 units/box)

All-In-One Drop Cell - Base

All-In-One Drop Cell - Base

User-friendly and robust interface between electrodes and instrumentation. Enables the use of microvolume (1–10 μL sample drops) with standard (10x6mm) thin-film (micro)electrodes. Includes the basic assembly parts for the different add-ons.

All-In-One Drop Cell - Base

Material: Aluminium base + methacrylate cover

Dimensions: 60 x 40 x 30 mm (W x D x H)

Contents: Interface + cable (male or female banana end)

Details: Easy and fast electrode replacement. Reusable - long life

ED-AIO-CELL

All-In-One Platform (1xAdd-on)

All-In-One Platform (1xAdd-on)

AIO drop cell base with one add-on for static or dynamic experimental conditions. Compatible with Flow, Batch or Thin-layer add-ons. The cell is also compatible with EEP platform.

All-In-One Platform (1xAdd-on)

Material: Aluminium base + methacrylate cover

Dimensions: 60 x 40 x 30 mm (W x D x H)

Contents: AIO Drop Cell + 1 Add-on (to be chosen) + cable (male or female banana end)

Details: Easy and fast electrode replacement. Different movable add-ons are available. Easy add-ons assembly (tool free). Reusable - long life

ED-AIO-CELL-1x

40 Products. View all

Returns

All the information that you should know about our returns policy...

More information

Contact

Contact us to solve your doubts or answer your questions. We can help you!

More information

Delivery

We ship the products under strict security measures, ensuring their protection...

More information

subscribe to our monthly newsletter