Standard dimensions
10 x 6 x 0.75 mm
Substrate
Glass
Microfluidic Stage
SU-8 resin
Channel width
250 µm / 1 mm (EC-cell)
Channel height
40 µm
Electrode material/thickness
Pt or Au / 150 nm
Basic three-electrode system combined with microfluidic chips by thin-film technologies. Working electrode is placed in the middle of the single-microchannel to get the highest performance. Improve the reproducibility and sensitivity of experiments.
Dimensions: 10 x 6 x 0.75 mm
Substrate: Glass
Microfluidic stage: EPON SU8 resin
Channel width: 250 µm / 1mm (EC-cell)
Channel height: 40 µm
Inlet / outlet: 0.7 mm Ø
Electrodes material: Ti / Au
Electrodes thickness: 50/150 nm
WE size: 0.3 mm2
Channel volume: 55 nL
Applications: Electroanalysis, flow systems, nanotechnology, chemical sensors, biosensors
Contents: 20 units/box
Dimensions: 10 x 6 x 0.75 mm
Substrate: Glass
Microfluidic stage: EPON SU8 resin
Channel width: 250 µm / 1mm (EC-cell)
Channel height: 40 µm
Inlet / outlet: 0.7 mm Ø
Electrodes material: Ti / Pt
Electrodes thickness: 50/150 nm
WE size: 0.3 mm2
Channel volume: 55 nL
Applications: Electroanalysis, flow systems, nanotechnology, chemical sensors, biosensors
Contents: 20 units/box
Two interdigitated WE with RE and AE integrated fully integrated and combined with a microfluidic channel. Enable the use of the same or different detection potential simultaneously. Enhance sensitivity and selectivity of experiments.
Dimensions: 10 x 6 x 0.75 mm
Substrate: Glass
Microfluidic stage: EPON SU8 resin
Channel width: 250 µm / 1mm (EC-cell)
Channel height: 40 µm
Inlet / outlet: 0.7 mm Ø
Electrodes material: Ti / Au
Electrodes thickness: 50/150 nm
Microelectrode width: 10 µm
Microelectrode gap: 10 µm
Number of fingers: 15 pairs
Channel volume: 55 nL
Applications: Impedance, capacitance and conductivity measurements, fuel cells
Contents: 20 units/box
Dimensions: 10 x 6 x 0.75 mm
Substrate: Glass
Microfluidic stage: EPON SU8 resin
Channel width: 250 µm / 1mm (EC-cell)
Channel height: 40 µm
Inlet / outlet: 0.7 mm Ø
Electrodes material: Ti / Pt
Electrodes thickness: 50/150 nm
Microelectrode width: 10 µm
Microelectrode gap: 10 µm
Number of fingers: 15 pairs
Channel volume: 55 nL
Applications: Impedance, capacitance and conductivity measurements, fuel cells
Contents: 20 units/box
Dimensions: 10 x 6 x 0.75 mm
Substrate: Glass
Microfluidic stage: EPON SU8 resin
Channel width: 250 µm / 1mm (EC-cell)
Channel height: 40 µm
Inlet / outlet: 0.7 mm Ø
Electrodes material: Ti / Au
Electrodes thickness: 50/150 nm
Microelectrode width: 5 µm
Microelectrode gap: 5 µm
Number of fingers: 30 pairs
Channel volume: 55 nL
Applications: Impedance, capacitance and conductivity measurements, fuel cells
Contents: 20 units/box
Dimensions: 10 x 6 x 0.75 mm
Substrate: Glass
Microfluidic stage: EPON SU8 resin
Channel width: 250 µm / 1mm (EC-cell)
Channel height: 40 µm
Inlet / outlet: 0.7 mm Ø
Electrodes material: Ti / Pt
Electrodes thickness: 50/150 nm
Microelectrode width: 5 µm
Microelectrode gap: 5 µm
Number of fingers: 30 pairs
Channel volume: 55 nL
Applications: Impedance, capacitance and conductivity measurements, fuel cells
Contents: 20 units/box
We ship the products under strict security measures, ensuring their protection...